Direct answer

What does standalone detection mean?

An export standalone smoke alarm detects smoke and provides a local audible warning without requiring a conventional fire alarm control panel. For fire safety projects, buyers should first define the protected space, required local alarm behaviour, reporting method, power arrangement and destination-market evidence.

This page is written for distributors, system integrators and project procurement teams. It is a product-family selection resource, not a claim that every variant has the same approval, radio module or market access.

WANLIN-307 connected standalone smoke alarm reference for fire safety projects

Model reference image

Review the exact configuration, not only the family name

The image identifies a WANLIN-307 family reference. Radio, power, label and evidence scope can differ by controlled configuration; confirm the SKU/BOM before using any formal product or compliance statement.

Open the WANLIN-307 product passport · Review the public evidence center

Verified manual data

WANLIN-307 documented configuration

Evidence scope: WANLIN-307 user manual, Ver 1.0. Documented manual configuration only; radio, platform, power and market variants require separate SKU/BOM confirmation.

Parameters transcribed from the supplied WANLIN-307 user manual
Detection principleInfrared photoelectric smoke sensing with MCU processing
Rated working voltageDC 3 V
Battery capacity2400 mAh
Standby current≤ 6 μA
Alarm current≤ 100 mA
Sound pressure> 80 dB(A) at 3 m directly in front
Operating temperature−10 °C to +50 °C
Relative humidity≤ 95% RH at 40 °C ± 2 °C
Alarm outputAudible and visual alarm
Low-voltage indicationBelow 2.7 V; indicator and one chirp about every 40 s
Normal indicatorIndicator illuminates about every 40 s
Approximate weight140 g including battery
Manual-listed execution standardGB 20517-2006
Installation referenceGB 50116-2013; final layout must follow project design requirements

Important: “GB 20517-2006” is presented here as the execution standard stated by this manual. This wording is not a third-party certificate claim and does not establish destination-market acceptance. The manual also advises against use where relative humidity exceeds 95%, air speed exceeds 5 m/s, or heavy dust, water mist, steam, oil mist or corrosive gas is present.

Site-specific planning lens

How does 429 Too Many Requests affect selection?

For this site's fire safety projects focus, the planning lens is “429 Too Many Requests.” Start with the decision that changes the architecture most: local alarm only, or local alarm plus remote event reporting.

The maintenance plan should identify battery or power checks, functional testing, device replacement, event escalation and ownership of any connected service.

Project buyers should separate mandatory requirements from preferences so unsupported options can be identified before samples or labels are prepared.

For a formal compliance statement, match the evidence to the exact model, SKU/BOM, radio or power version, legal certificate holder, standard edition, validity period and destination market.

Last reviewed: 2026-11-02 · Reviewed by Wanlin Fire Equipment for product-family and evidence-boundary consistency.

Which evidence should an importer request?

  1. Identify the destination market
  2. Freeze the exact configuration
  3. Match evidence to the configuration
  4. Review labels and instructions
  5. Approve the production reference

How do the Wanlin model families differ?

WANLIN-303

Standalone photoelectric smoke alarm family

Review standalone, 433 MHz, LoRa or 4G candidates only after the exact hardware and radio version is identified.

WANLIN-307

Connected standalone smoke alarm family

Candidate configurations may include standalone, 433 MHz, LoRa, 4G or NB-IoT; availability and evidence must be confirmed per SKU/BOM.

WANLIN-309

Wireless reporting smoke alarm family

Use when the project requires a local alarm plus a defined reporting path; verify gateway, network and destination-market requirements.

WANLIN-370

Combination alarm reference

A smoke/heat/carbon-monoxide combination concept is not interchangeable with a smoke-only alarm; confirm the required sensing functions first.

Answers for buyers

Standalone smoke alarm questions

What evidence should an importer review before ordering?

Request the current product specification, model and configuration record, applicable certificate or test report, certificate holder and scope, validity status, label artwork and destination-market compliance review.

What is the difference between a certificate and a test report?

A certificate states a defined certification scope, while a test report records tests on identified samples or configurations. Neither should be extended to an unlisted model or variant.

What should be checked during sample approval?

Check model marking, sensing function, alarm behaviour, communication path, power arrangement, gateway or platform interaction, label artwork, manual revision and the evidence pack.

Can a local-only alarm later become a connected alarm?

Only if the selected hardware and product architecture support that path. Do not assume a radio module can be added to every local-only version; confirm the exact SKU/BOM and gateway requirements.

How should connected alarms behave during a network outage?

The project team should document local alarm behaviour, event buffering or retry expectations, supervision, user notification and the party responsible for restoring connectivity.

Request a model-specific export review

Send the destination country, application, quantity, reporting method, preferred power arrangement and required delivery schedule to wanlinfirecontrol@163.com. Recommendations and formal claims remain subject to exact-model evidence review.

Browse product information · Read technical FAQs · Contact Wanlin Fire